TLV EF200 Stainless Steel Wafer Type Vortex Flowmeter
Main body components made of stainless steel
Wafer type (flangeless) ends for installation between flanges to BS EN 1092-1 (PN10 – PN40), ASME B16.5 (Class 150 & 300) or JIS B2220 (10k & 20k)
Reading accurate to within 0.75% depending on medium and measurement type
DSC (Differential switched capacitance) sensor supports a wide measurement range and offers high thermal shock, water hammer and vibration resistance
Built-in flow computer calculates mass flow based on measured volume flow and temperature from built-in thermal sensor
Capable of simultaneous pulse (interval) and analogue (instantaneous) output
Low pressure drop through meter body
Suitable for use with various fluids including air and water as well as saturated or superheated steam
IP67 rated
No moving parts mitigating the need for maintenance
Recommended transmitter power input: 24v DC
Maximum operating pressure: Up to 49.6 bar depending on flange type
Maximum operating pressure: 400°C